Ice Rinks

masthead-logo-icon

Water Treatment Solutions for Ice Rinks

Chardon Labs Expert Ice Rink Water Treatment

Mechanical rooms for ice arenas are some of the most complicated and diverse systems in the world of refrigeration. When your ice rink was designed, many factors and variables were considered, depending on your geographic location, seasonal length of operation and water quality.

Chardon Laboratories has the knowledge and experience to recognize the differences from rink to rink and develop a customized ISO 9001-certified water management plan to protect this equipment from scale, corrosion and biological pathogens such as Legionella.

The Importance of Cooling Tower and Evaporative Condenser Water Treatment for Ice Rinks

Treating water and keeping heat transfer surfaces problem-free drastically increases equipment efficiency.

Ice arenas use an air-cooled tower or evaporative condenser to remove heat from the ice sheet, cool compressor heads or increase water quality. Consider hiring cooling tower and evaporative condenser water treatment for your facility, as the process can:

  • Improve efficiency: The metal surfaces of cooling towers and evaporative condensers are susceptible to corrosion, pitting, scaling and biofilm. Preventing heat transfer blockages will increase your equipment’s efficiency.
  • Enhance energy savings: Chemical water treatment means less water and energy need to be utilized to cool your system. The amount of water cycles can be optimized to save as much water as possible before it is flushed out. This is tailored for every system and highly depends on your local area’s water quality.
  • Increase safety: When owning an ice skating rink, visitor safety is a top priority. Keeping your ice skating rink at the right temperature will ensure it stays frozen solid, reducing the risk of potential skater injuries.
  • Extend your season: If you live in an area that experiences extremely warm springs and summers, you can still offer indoor ice skating with a cooling tower and evaporative condenser. This way, your business can take advantage of the off-season.

For Ice Rink Managers

Rink managers and their facility maintenance are often seen performing every task in the building, and we understand how the long days turn into long nights. Why not let the trained professionals at Chardon Labs protect the waterside of your mechanical room? With increased efficiency, enhanced equipment life and less downtime, our water management plans for hockey rinks more than pay for themselves.

Remote Monitoring Control Systems

When purchasing a new galvanized cooling tower or evaporative condenser, it is important to note the metallurgy of the system. Equipment manufacturers call out very specific parameters for the water chemistry during the passivation period. This information can be found in your operator’s manual and on a sticker on the equipment itself. Should you have a warranty claim and cannot produce evidence that your water has been kept within the manufacturer’s specifications, your warranty will be denied. Chardon Labs offers remote monitoring to ensure that the tower is passivated correctly. It’s like having affordable insurance for your new equipment!

Contact Us

    lock-icon

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Our Cooling Tower Treatment Services for Your Ice Rink

    We are an official U.S. Ice Rink Association vendor. Find us at the North American Rink Conference & Expo!

    At Chardon Labs, we take cooling tower treatment services seriously. Trust us to provide high-quality solutions at affordable prices. Here is a quick look at some of the treatments we offer for your ice rink.

    Start With System Testing and Reporting

    If you already have a cooling tower, we will test your current system’s efficiency. We will report its status and track its condition to keep everything working smoothly.

    Create a Management Plan

    Factors vary from rink to rink and must be considered when discussing a water management plan. We work closely with your mechanical contractor to develop a plan to keep your condenser water within the manufacturer’s specifications. Here are some of the important ice rink water management factors to consider:

    • Pump configurations
    • Refrigerant type
    • Skin temperatures
    • Operating hours
    • Heat loads
    • Metallurgy of system equipment
    • Municipal water supply

    Provide Contaminant Solutions

    Keeping your cooling tower free from contaminants can increase its efficiency and your rink’s safety. We can help prevent and rid your facility of common contaminants, such as:

    • Bacterial growth: A cooling tower is often damp and dark — the ideal environment for bacteria, fungi, algae and viruses to grow. Chardon Labs is aware of these conditions and will take steps to address and treat bacterial growth safely.
    • Corrosion: Since corrosion can occur with water conductivity, it is common in cooling towers. Our specialists can treat your cooling tower with epoxy, corrosion inhibitors or other multi-step pH management approaches.
    • Scaling: Minerals can build up in your cooling tower over time and reduce its efficiency. Our team will remove it with an efficient cleaning process, utilizing conductivity monitoring, chemical monitoring and blowdown removal.
    cta-bg02

    Contact Chardon Labs for Ice Rink Water Treatment Solutions

    Want consistent water treatment service that improves equipment efficiency and helps prevent problems?

    Once you partner with us, you become part of our family. We will schedule routine maintenance at a quoted yearly cost and can also provide emergency maintenance services. Connect with us today for more information on our water treatment solutions for your ice rink!

    ble prices

    Together, we will develop a customized water treatment plan to meet your specific needs. Contact us to request a free survey of your water system today.

    Contact Us